Page 213 - Catalog
P. 213
CABLERAIL BY FEENEY®
Step-by-Step Installation for Wood Frames
Installing the Standard 1/8" Cable System is easy. Just follow these simple steps:
1 2 3 4 5
1 2 3 4 5
Mark drill hole locations Drill holes in posts. Hole Insert Protector Sleeves Insert the Threaded Lace the free end of
on posts. diameter depends on at necessary locations. Terminal through the the cable through the
cable size and type of Tap in until flush. Terminal end post and
To minimize cable attach a flat washer intermediate posts and
®
deflection, space fitting. See chart below. and Snug-Grip Quick-Connect SS end
®
cables no more than Protector Sleeves Washer-Nut. Spin post. Slide-on a flat
3 inches apart and have prevent abrasion at the nut 2 full turns. washer and Quick-
®
a post or vertical spacer angled transitions on Strong resistance will Connect SS fitting until
at least every 3 feet. Threaded Term. Post Intermediate Posts Quick-Connect Post wood posts (e.g. stair be felt as the Snug- they rest against the
Also, straight runs of Cable Size transition posts or Grip threads engage; face of the post.
®
cable (no turns/dips) outside faces of double so hold the Terminal Use a Lacing Needle
should not exceed 70 1/8" 5/16" 1/4" 3/8" corner posts.) shaft with pliers. if snagging becomes
feet. Runs with corners 3/16" 3/8" 1/4" 9/16" a problem.
(2 bends at most) should
®
not exceed 40 feet. (See If desired, Quick-Connect SS
Frame Requirements on posts may be through drilled
previous page.) at 1/4" and then counter-
bored with the recommended
Quick-Connect SS drill to Use Beveled Washers for stair termination posts with
®
countersink the fitting. angled holes. Available for Threaded Terminal and
Quick-Connect SS fittings. Always install the Quick-
®
Connect SS fittings in the top stair post to prevent rain STAINLESS & CABLE RAILING
®
water from running down the cable into the fittings.
6 7 8 9 10
6 7 8 9 10
Hold the Tension the cables by Use hacksaw, Use cable cutters Snap on end caps
®
Quick-Connect SS holding the Threaded reciprocating saw, or or electric grinder with over the exposed
®
fitting with one Terminal shaft with Vise- electric grinder with cut-off disk to trim the Quick-Connect SS
hand and pull the Grip pliers and spinning cut-off disk to saw off excess cable. Grind fittings and the
®
cable tight with the the Snug-Grip® Washer- the excess threads as flush the exposed cable Snug-Grip Washer-
other. The fitting Nuts with a wrench. A close to the Snug-Grip® ends with an electric Nuts. You’re done.
automatically locks Feeney Tension Gauge Washer-Nut as possible. grinder. SteelRenewal™ &
when you release may be used to check Touch-up with electric SteelProtect™ can
the cable. uniform tension. grinder. The special be used to clean
Snug-Grip® threads and provide lasting
prevent the nut from protection of stainless
Recommended loosening. steel cable and parts.
cable tensioning Important Note: If using electric or pneumatic tools to tighten the Washer Nuts,
sequence spin the nuts very slowly otherwise they will heat-up causing the threads to seize.
11 Cables can terminate or run through corner posts
9
11 7 Terminating Continuous
9 5
7 3
5 1
3 2
1 4
2 6
4 8
6 10
8 12
10 SINGLE WOOD POST DOUBLE WOOD POSTS DOUBLE WOOD POSTS
12 Offset drill holes at least 1/2”
T: 800.784.7444 T: 908.757.2323 F: 908.757.3439
AISALES@ARCHIRONDESIGN.COM ARCHIRONDESIGN.COM 211