DASMA SAFETY GUIDE


            SWING GATE REQUIREMENTS


            Only install the operator on gates used for vehicular traffic. Be sure to direct pedestrians to a separate entry and exit.
            Refer to the illustrations. The gate site must be designed so persons do not come in contact with the vehicular gate
            while it is moving. Signs must be posted to warn pedestrians to stay clear of the gate’s entire travel path.
            A separate pedestrian entry/exit must be clearly visible and promote pedestrian usage.

                                                                                M ount ac c ess c ontrol
                             Public Side
                                                                                ( 1 . 8 m)  b ey ond  the gate.
                                      B e sure to plac e the
                                WARNING  W A R N I N G signs on b oth
                               sid es of the ac c ess point in c lear v iew of v ehic les.    P hoto ey e
                               For y our rec ord s,  tak e a  photograph of the   ( pub lic  sid e)
                                               P hoto ey e                         P hoto
                                               ( pub lic  sid e)                   ey es

                                         WARNING
                                                              ZONE
                                                                            ENTRA AP PMENT
                                                  ENTRAPMENT        E d ged ge  ENTRAPMENT   Curb  R e e tor
                                                                                            for P hoto
                                                                                            E y e
                                                                    E
                                                                    sensor
                                                                    sensor
                                    E arth ground                                       A
                                              Curb
                                                                         ENTRAPMENT
                                                                           ZONE
                             P ed estrian gate loc ated
                             near the swing gate.
                             M ak e sure a separate walk -through entranc e is   Secure Side
                             av ailab le and  its ped estrian path is c learly  d esignated .  View A
                                                            Cross Section
                          Hinge Mount Location: Entrapment Considerations
                                                      A
                                   Closed Gate
                          A  I f spac e is greater than 4 inc hes            Closed Gate
                                                                         W ith the hinge mounted  on
                                                                         the c orner of the pilaster,
                            in this area is req uired .
                                                                                       A
                                                        B                the entrapment z one         is
                          B  I f spac e is less than 1 6  inc hes
                                                      Gate               not req uired  for this area.   Gate
                            in this area is req uired .
                                                     pened                                    pened
                            ( A S T M  F2200:  7 . 1 . 1 . 1  and  7 . 1 . 1 . 2)  O          O

            BASE OF SWING & SLIDE GATES

            Gates must have smooth bottom edges, no protrusions should exist. If gate hardware or sensors protrude, they must have
            smooth surfaces free of any sharp cutting edges that do not exceed ½ inch (13 mm) beyond the base of the gate.