Accelerometer Bias Model Parameters (0x0D,0x1C)
Description |
Accelerometer Bias Model Parameters |
|
Notes |
Noise values must be greater than 0.0 |
|
Parameter Name | Data Type | Description |
Field Length | u8 | 3 |
Descriptor | u8 | 0x1C |
Function Selector | u8 |
This command supports the following MIP function selectors:Write Read Save Load Default
[WRSLD]
|
Beta
[W]
|
Vector3f | Accel Bias Beta [1/second] |
Noise
[W]
|
Vector3f | Accel Noise 1-sigma [meters/second^2] |
Response Data | Data Type | Description |
Response Length | u8 | 2 |
Response Descriptor | u8 | 0x8B |
Beta | Vector3f | Accel Bias Beta [1/second] |
Noise | Vector3f | Accel Noise 1-sigma [meters/second^2] |